  1. Symptoms

    From 9:28am Pacific Time on 8 March 2016, applications on the cloud.gov PaaS that relied on outbound traffic to reach the services they depended on became unavailable, and at one point every application on cloud.gov was down.

    Trigger

    At 9:28am Pacific Time on 8 March 2016 a contractor at Aquilent changed the AWS security group settings, one of several changes made in the process of achieving ATO for the platform.

    Root cause
    Component
    Contributing factor
    –
    Remediation
    • Added exceptions for individual applications, which restored some of them
    • Rolled back the security group change, which restored all applications
    Action items
    • Put all security group configuration into version control and make changes through pull requests
    • Monitor the applications running on cloud.gov and alert the cloud.gov team when they do not work as expected
    • Use CF security groups instead of AWS security groups and make the current rules visible to the cloud.gov team and the teams using it
    • Create a notification system to reach the key contact of each application on the platform
    • Create a more accurate staging environment to test changes like this
  2. Symptoms

    At 4.50am Melbourne time on Sunday 7 February (evening of 6 February UTC), FastMail became unavailable and stayed unreachable for almost two hours. Traffic to FastMail's public IP range never made it into FastMail's own network.

    Trigger

    The GRE tunnels between Level 3 and NYI, which carried FastMail's filtered traffic into its network, went down.

    Root cause
    Component
    Contributing factor
    Detection

    NYI, the datacentre provider, noticed the failure quickly.

    Remediation
    • NYI escalated with Level 3's support until FastMail's public IP ranges were pointed back to NYI
    Action items
    • Go back to DDoS protection from Black Lotus under NYI's explicit control
    • Build nginx frontends in the Los Angeles datacentre that reach NYI over the secondary network, and point DNS to them if NYI's primary network fails
    • Add hardware in Amsterdam and change the delivery system so it depends less on NYI
    • Work with NYI to understand its processes for detecting and responding to network faults
    Lessons

    Much of FastMail's and NYI's reliability had come from NYI controlling its own infrastructure. With protection always on at Level 3, NYI could not restore the routes itself, and FastMail calls the resulting delay in restoring service unacceptable.

  3. Symptoms

    From 12:47 AM PDT on 21 April 2011, a subset of Amazon EBS volumes in one Availability Zone of the US East Region could no longer serve reads or writes, and EC2 instances that tried to use them got stuck as well. AWS called these "stuck" volumes. EBS API calls across the whole US East Region also returned high error rates and latencies during two periods on the first day.

    Trigger

    During a routine network change to upgrade the capacity of the primary EBS network in one Availability Zone, traffic was to be shifted off one of the redundant routers. The shift was executed incorrectly and sent the traffic onto the lower-capacity replication network instead of the other primary router, which could not carry it.

    Root cause
    Component
    Contributing factor
    Remediation
    • Rolled back the incorrect traffic shift, which restored network connectivity
    • Disabled all new Create Volume requests in the affected Availability Zone at 2:40 AM PDT
    • Disabled all communication between the degraded EBS cluster and the EBS control plane from 8:20 AM PDT
    • Stopped EBS servers in the degraded cluster from futilely contacting other servers for free space
    • Changed the EBS control plane so new EBS-backed instance launches stopped failing
    • Moved spare server capacity physically from across the US East Region into the degraded cluster
    • Adjusted the negotiation throttles so the new servers could join without flooding the old ones
    • Built a separate EBS control plane partitioned to the affected zone and finer-grained throttles, then processed the backlog
    • Restored the remaining volumes from S3 snapshots taken early in the event
    • Restored volumes on failed machines that had no snapshot after forensic work
    • Intervened by hand on the RDS multi-AZ instances that did not fail over automatically
    Action items
    • Audit the change process and add automation to prevent the traffic shift mistake
    • Change capacity planning and alarming to keep the extra safety capacity needed for large recovery events
    • Change the retry logic in EBS nodes to back off harder and reconnect to previous replicas instead of searching for new nodes
    • Test and deploy the fix for the race condition that crashed EBS nodes
    • Fix the RDS bug that kept multi-AZ instances from failing over automatically
    • Improve the EBS control plane timeout logic to prevent thread exhaustion when one zone's cluster is slow
    • Make the EBS control plane aware of Availability Zones so it sheds load when over capacity
    • Move more EBS control plane functions into per-cluster services that run in the same zone as the cluster
    • Offer multiple Availability Zones to Amazon VPC customers
    • Provide better tools for building multi-AZ applications that survive the loss of a zone
    • Host free webinars and publish whitepapers on fault-tolerant architecture
    • Build the fine-grained control and throttling used in recovery into the EBS nodes and automate the recovery models
    • Look at changes that keep volumes working while a cluster is degraded, including the ability to take a snapshot of a stuck volume
    • Send more frequent and detailed customer updates and staff developer support more widely during events
    • Develop tools that show through the APIs whether instances are impaired
    Lessons

    AWS writes that with more spare capacity the cluster would have absorbed the re-mirroring requests without a storm, and that it now understands how much capacity large recovery events need. The event also showed that the EBS control plane let a failure in one Availability Zone affect the others, so more work is needed to make zones behave as if completely independent. AWS adds that some customers had critical components in a single zone, and that multi-AZ deployments need to become easier to design and run.

Check your cluster for this

These 39 cases involve BGP routing and Network control plane (SDN). kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause10

Faulty deployment3 cases

  1. IL-0354 Fly.io private networking (6PN) broke for some machines after edges received gateway /80 routes
    Fly.io2026
  2. IL-0563 Linode servers lost connectivity in all data centers as route servers built incomplete BGP route tables
    Linode2025
  3. IL-0530 Virtual router controllers in us-central1 ran out of memory in a loop, cutting networking for new and migrated VMs

Cloud provider outage4 cases

  1. IL-0463 Secure Connect connectors timed out after a GKE control plane upgrade left Harness's internal load balancer unreachable
  2. IL-0368 PlanetScale's control plane went down and some database branches failed queries during the AWS us-east-1 outage
  3. IL-0261 Discord went fully offline twice as short network losses on Google Cloud sessions nodes wedged Erlang distribution
  4. IL-0494 Netlify's central load balancer IP stopped responding when Rackspace null-routed it in a DDoS, and A-record sites hung

Configuration change8 cases

  1. IL-0400 Public sector sites across Wales lost connectivity for over 8 hours as a PE router wrongly advertised a default route
    PSBA2026
  2. IL-0473 Jenkins infrastructure went fully down after a pod IP range fix deleted every AKS node pool and could not recreate them
  3. IL-0541 Two Twingate Relay clusters were discoverable but unreachable, so Clients and Connectors could not attach to them
  4. IL-0225 An IGP purge command made every Microsoft WAN router recompute routes, causing global latency, timeouts and packet loss
  5. IL-0266 Eqiad routers looped traffic between each other after a BGP MED change and could not reach other sites' public IPs
  6. IL-0539 KT's internet service failed nationwide for about 89 minutes as wrong routes spread from one router in Busan
    KT2021
  7. IL-0228 IPv4 routing across OVHcloud's global network broke after a router change put the full internet routing table into OSPF
  8. IL-0519 Apps on the cloud.gov PaaS became unavailable after an AWS security group change blocked their outbound traffic

Capacity exhaustion2 cases

  1. IL-0350 Hosts in an IONOS TXL cluster lost connectivity when an InfiniBand fabric resweep failed on a full multicast table
  2. IL-0472 Node-to-pod traffic and DNS failed on Tinder's 605-node Flannel cluster when every node's ARP cache passed gc_thresh3
    Tinder2019

Operator error6 cases

  1. IL-0349 IONOS Private Cloud in Berlin lost management access, storage and VM internet routing after a VLAN change
  2. IL-0244 A queued pull request destroyed the EKS subnet route table associations and Cloud Platform services went offline
  3. IL-0221 A backbone maintenance command disconnected all Facebook data centers, and its DNS servers withdrew their BGP routes
    Meta2021
  4. IL-0245 Acquia Cloud Enterprise sites in US-East went down when their web servers could no longer reach the Memcache servers
    Acquia2019
  5. IL-0431 During Mackerel's move to AWS, PostgreSQL failed over to a replica that had stopped replicating, losing an hour of data
    Hatena2017
  6. IL-0337 EBS volumes in one US East Availability Zone got stuck after a network change cut EBS nodes off from their replicas

Breaking change in an upgrade1 case

Organisation
  1. IL-0227 Most Heroku dynos in Private Spaces lost outbound connectivity after an automated OS update restarted host networking
    Heroku2025

Software defect7 cases

  1. IL-0233 A VPC control plane release broke IP alias routes in Nebius eu-west1, and Managed Kubernetes pods lost connectivity
    Nebius2025
  2. IL-0347 About 25% of Scaleway FR-PAR-1 hypervisors lost VPC connectivity when both VPC BGP route reflectors got stuck
  3. IL-0529 New Google Cloud VMs and other instances came up without network connectivity in all zones after VPC controllers stopped
  4. IL-0342 DigitalOcean's AMS3, LON1 and SFO2 data centers lost Internet connectivity in repeated waves as edge routers failed
  5. IL-0344 Linode's US-West data centers in Fremont and Santa Clara lost connectivity as the fibre circuits between them failed
    Linode2023
  6. IL-0222 Google Cloud US regions had heavy packet loss and some went unreachable after the network control plane was descheduled
  7. IL-0396 New or live-migrated GCE instances, VPN tunnels and network load balancers were unreachable on public IPs for over 2h

Dependency failure6 cases

  1. IL-0526 OpenStreetMap.org went offline, then read-only, for 56 hours after HE.net routing equipment cut both fibre uplinks
  2. IL-0509 SourceHut was down for 170 hours after a DDoS led its upstream network to null-route the PHL datacenter's subnet
  3. IL-0259 Outbound packets from Fastmail did not reach part of the internet for about 19 hours, cutting off 3-5% of customers
  4. IL-0267 Wikimedia's eqsin cache site went unreachable when both of its transport links to the core data centers were down
  5. IL-0358 Packet Public Cloud locations had high latency and unreachable paths from routing loops and blackholed traffic
    Packet2019
  6. IL-0258 FastMail was unreachable for almost two hours when the GRE tunnels carrying its traffic from Level 3 went down

DNS or network fault1 case

Contributing factor
–
Organisation
  1. IL-0423 A core switch failure in Paperspace's NY2 region cut VMs off their network file system and left them read-only

Hardware failure1 case

  1. IL-0525 OpenStreetMap.org went offline for 7h 27m when its uplink switch lost power during a data-centre power feed maintenance