  1. Symptoms

    On 13 March 2025 practically every pod of Nebius Managed Services for Kubernetes in the eu-west1 region lost network connectivity for at least some time between 13:36 and 18:11 UTC. Packets for the affected IP alias routes were not processed by the data plane. The eu-north1 region was not affected.

    Trigger

    A release of a VPC control plane component in eu-west1, deployed to canaries from 13:36 UTC and to all other nodes from 14:35 UTC, changed route distinguisher values for a new feature. The change made a long-standing bug in the handling of route announcements take effect for the update messages of Managed Kubernetes pods.

    Root cause
    Component
    Contributing factor
    Remediation
    • Restarted the host VPC component on the affected nodes one node at a time
    • Restarted the host VPC component on the remaining nodes in parallel once the restart was known to fix the problem
    Action items
    • Fix the bug in the VPC host component itself
    • Add an alert on a diverging number of routes
    • Add an alert on the number of drops in the data plane
    • Develop a way to reset endpoints without restarting the host VPC component
    • Move the VPC's persistent e2e test virtual machines to canary hosts
    • Add persistent e2e tests for Managed Services for Kubernetes
    • Run e2e tests more often
    • Add a deployment stage in which non-critical internal services receive updates first
    Lessons

    The failure needed both an existing IP alias at release time and a particular order of node updates, and neither the testing installation nor the canaries met both, so neither caught it. Missing alerts on technical metrics that deviate from normal, here the number of routes and the number of drops, made the response much slower.

  2. Symptoms

    At 04:01 UTC on 15 December 2024, StatusCake monitoring sent SMS alerts that OpenStreetMap.org was unreachable. The website and the mapping API had gone completely offline at 03:53 UTC.

    Trigger

    HE.net's routing equipment in Amsterdam failed at 03:53 UTC on 15 December 2024.

    Root cause
    Component
    Contributing factor
    Detection

    StatusCake monitoring detected the outage at 04:01 UTC and sent SMS alerts, and the incident was reported to the operations team at once.

    Remediation
    • Activated a read-only backup instance of OpenStreetMap.org in Dublin
    • Brought a new Equinix Internet link into service in Amsterdam, bypassing HE.net and restoring full functionality
    • HE.net replaced its routing hardware and restored its service, and routing through HE.net resumed
    Action items
    • Move to a multi-ISP architecture so another provider can take over when one fails
    • Research backup ISPs for the Amsterdam servers, including BGP and keeping HE.net as a fallback
    • Add deeper route and latency monitoring and an automated escalation protocol
    • Hold failover drills for switching between ISPs and keep replication up to date
    • Agree SLAs with HE.net and Equinix Internet with defined escalation procedures and response times
    • Prepare the 4G out-of-band system as a manual fallback uplink that can sync Postgres replication data, and upgrade its hardware
    • Document outage communication procedures and delegate communication during outages
    • Investigate decoupling the OAuth service so authentication keeps working while the database is read-only
    Lessons

    Relying on HE.net alone left the Amsterdam servers with a single point of failure, so OpenStreetMap will keep multiple upstream providers. The 4G out-of-band link proved invaluable and should be able to carry data synchronisation. Resumed replication would have restored editing faster than the read-only backup. Frequent contact with the ISP gave no useful estimates, so the SLA needs to be better understood. Alerting on upstream connectivity needs refining, and a read-only OpenStreetMap.org also blocked logins to services that were not affected, because it could not save new tokens.

  3. Symptoms

    On 18 October 2024, from 7:50 to 8:01 UTC, about 25% of the hypervisors in Scaleway's FR-PAR-1 availability zone lost VPC connectivity with the rest of the region, and products that use VPC failed with them. Public internet connectivity and Elastic Metal VPC connectivity were not affected.

    Trigger

    At 6:20 UTC a Top of Rack switch in FR-PAR-1 had a software crash. One of the two BGP route reflectors for VPC ran on a hypervisor in that rack and was left in an abnormal state.

    Root cause
    Component
    Contributing factor
    Detection

    Health-check monitoring on both route reflectors detected the anomaly, and the Scaleway Customer Excellence and SRE teams detected the customer impact and opened an incident.

    Remediation
    • Fixed both VPC route reflectors by manual action
    Action items
    • Fixed the autohealing mechanism that had failed to fix route reflectors stuck in a stale state; the fix is https://github.com/FRRouting/frr/pull/17163
    • Run different software versions on the route reflectors so a single bug cannot stop several instances
    • Investigate the software issue that left the route reflectors in a stale state
  4. Symptoms

    On 20 September 2024 at 11:24 the Cloud Platform team received high priority Pingdom alerts for services on the live cluster, and from 11:26 teams reported in the #ask channel that services were unavailable. Users reported that services could not be resolved.

    Trigger

    At 11:21 the infrastructure-vpc-live-1 pipeline was unpaused, and a pull request that had been waiting in its queue ran automatically.

    Root cause
    Component
    Contributing factor
    Detection

    High priority Pingdom alerts for live cluster services reached the Cloud Platform team at 11:24, and users reported that services could not be resolved.

    Remediation
    • Ran terraform apply locally to rebuild the subnet route table associations
    Action items
    • Review and update the process for pausing and resuming infrastructure pipelines so every team member knows its implications
    • Find a way to hold queued pull requests while manual infrastructure updates are under way
    • Find ways to isolate the plan and apply tasks of infrastructure pipelines better
  5. Symptoms

    On 16 June 2024, from around 10:30 UTC, users could not interact with Gradient notebooks and Core VMs in Paperspace's NY2 region. A large number of virtual machines lost network access to the Network File System they resided on and went into Read-Only (RO) mode, so customers could not write to them. Network connectivity came back by 18:20 UTC, but the affected VMs stayed unavailable in RO mode until the next day, and after Core was fixed the Gradient platform still ran with degraded performance while it recovered.

    Trigger

    A core switch in NY2 failed, and the resulting spike in traffic degraded network performance.

    Root cause
    Component
    Contributing factor
    –
    Remediation
    • Restored network connectivity to the affected VMs by 18:20 UTC on 16 June
    • Returned the affected VMs from Read-Only to Read-Write mode between 5:58 and 12:23 UTC on 17 June
    Action items
    • Redesign the network
    • Install new equipment
Check your cluster for this

These 39 cases involve BGP routing and Network control plane (SDN). kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause10

Faulty deployment3 cases

  1. IL-0354 Fly.io private networking (6PN) broke for some machines after edges received gateway /80 routes
    Fly.io2026
  2. IL-0563 Linode servers lost connectivity in all data centers as route servers built incomplete BGP route tables
    Linode2025
  3. IL-0530 Virtual router controllers in us-central1 ran out of memory in a loop, cutting networking for new and migrated VMs

Cloud provider outage4 cases

  1. IL-0463 Secure Connect connectors timed out after a GKE control plane upgrade left Harness's internal load balancer unreachable
  2. IL-0368 PlanetScale's control plane went down and some database branches failed queries during the AWS us-east-1 outage
  3. IL-0261 Discord went fully offline twice as short network losses on Google Cloud sessions nodes wedged Erlang distribution
  4. IL-0494 Netlify's central load balancer IP stopped responding when Rackspace null-routed it in a DDoS, and A-record sites hung

Configuration change8 cases

  1. IL-0400 Public sector sites across Wales lost connectivity for over 8 hours as a PE router wrongly advertised a default route
    PSBA2026
  2. IL-0473 Jenkins infrastructure went fully down after a pod IP range fix deleted every AKS node pool and could not recreate them
  3. IL-0541 Two Twingate Relay clusters were discoverable but unreachable, so Clients and Connectors could not attach to them
  4. IL-0225 An IGP purge command made every Microsoft WAN router recompute routes, causing global latency, timeouts and packet loss
  5. IL-0266 Eqiad routers looped traffic between each other after a BGP MED change and could not reach other sites' public IPs
  6. IL-0539 KT's internet service failed nationwide for about 89 minutes as wrong routes spread from one router in Busan
    KT2021
  7. IL-0228 IPv4 routing across OVHcloud's global network broke after a router change put the full internet routing table into OSPF
  8. IL-0519 Apps on the cloud.gov PaaS became unavailable after an AWS security group change blocked their outbound traffic

Capacity exhaustion2 cases

  1. IL-0350 Hosts in an IONOS TXL cluster lost connectivity when an InfiniBand fabric resweep failed on a full multicast table
  2. IL-0472 Node-to-pod traffic and DNS failed on Tinder's 605-node Flannel cluster when every node's ARP cache passed gc_thresh3
    Tinder2019

Operator error6 cases

  1. IL-0349 IONOS Private Cloud in Berlin lost management access, storage and VM internet routing after a VLAN change
  2. IL-0244 A queued pull request destroyed the EKS subnet route table associations and Cloud Platform services went offline
  3. IL-0221 A backbone maintenance command disconnected all Facebook data centers, and its DNS servers withdrew their BGP routes
    Meta2021
  4. IL-0245 Acquia Cloud Enterprise sites in US-East went down when their web servers could no longer reach the Memcache servers
    Acquia2019
  5. IL-0431 During Mackerel's move to AWS, PostgreSQL failed over to a replica that had stopped replicating, losing an hour of data
    Hatena2017
  6. IL-0337 EBS volumes in one US East Availability Zone got stuck after a network change cut EBS nodes off from their replicas

Breaking change in an upgrade1 case

Organisation
  1. IL-0227 Most Heroku dynos in Private Spaces lost outbound connectivity after an automated OS update restarted host networking
    Heroku2025

Software defect7 cases

  1. IL-0233 A VPC control plane release broke IP alias routes in Nebius eu-west1, and Managed Kubernetes pods lost connectivity
    Nebius2025
  2. IL-0347 About 25% of Scaleway FR-PAR-1 hypervisors lost VPC connectivity when both VPC BGP route reflectors got stuck
  3. IL-0529 New Google Cloud VMs and other instances came up without network connectivity in all zones after VPC controllers stopped
  4. IL-0342 DigitalOcean's AMS3, LON1 and SFO2 data centers lost Internet connectivity in repeated waves as edge routers failed
  5. IL-0344 Linode's US-West data centers in Fremont and Santa Clara lost connectivity as the fibre circuits between them failed
    Linode2023
  6. IL-0222 Google Cloud US regions had heavy packet loss and some went unreachable after the network control plane was descheduled
  7. IL-0396 New or live-migrated GCE instances, VPN tunnels and network load balancers were unreachable on public IPs for over 2h

Dependency failure6 cases

  1. IL-0526 OpenStreetMap.org went offline, then read-only, for 56 hours after HE.net routing equipment cut both fibre uplinks
  2. IL-0509 SourceHut was down for 170 hours after a DDoS led its upstream network to null-route the PHL datacenter's subnet
  3. IL-0259 Outbound packets from Fastmail did not reach part of the internet for about 19 hours, cutting off 3-5% of customers
  4. IL-0267 Wikimedia's eqsin cache site went unreachable when both of its transport links to the core data centers were down
  5. IL-0358 Packet Public Cloud locations had high latency and unreachable paths from routing loops and blackholed traffic
    Packet2019
  6. IL-0258 FastMail was unreachable for almost two hours when the GRE tunnels carrying its traffic from Level 3 went down

DNS or network fault1 case

Contributing factor
–
Organisation
  1. IL-0423 A core switch failure in Paperspace's NY2 region cut VMs off their network file system and left them read-only

Hardware failure1 case

  1. IL-0525 OpenStreetMap.org went offline for 7h 27m when its uplink switch lost power during a data-centre power feed maintenance