27 to 31 of 39

  1. Symptoms

    At 09:20 CET on 13 October 2021, during a planned change on a router, IPv4 traffic across OVHcloud's whole network stopped being routed, while all IPv6 traffic stayed reachable. The team detected a problem with the router's performance at 09:21 CET and escalated at once.

    Trigger

    A planned change to a router in the Vint Hill datacentre in the United States, meant to strengthen anti-DDoS protection, included a command to regulate the redistribution of BGP into OSPF, and the router did not interpret that command correctly.

    Root cause
    Component
    Contributing factor
    Detection

    At 09:21 CET the team detected a problem with the router's performance and started the escalation process.

    Remediation
    • Disconnected the optical equipment to isolate the router's connectivity
    • Powered off the faulty router
    • Stabilised connectivity to restore the remaining services
    Action items
    • Re-evaluate the change procedure for this type of equipment, which applies the command line natively
    • Strengthen the related change process
  2. Symptoms

    On 4 October 2021 Facebook's platforms went down worldwide: every connection in Facebook's global backbone network was lost, and the data centers were cut off from each other and from the internet. The rest of the internet could no longer find Facebook's servers, because Facebook's authoritative DNS servers had become unreachable.

    Trigger

    During routine maintenance of the backbone, a command was issued to assess the availability of global backbone capacity, and it unintentionally took down all connections in the backbone network.

    Root cause
    Component
    Contributing factor
    Remediation
    • Sent engineers onsite to the data centers to debug the issue and restart systems
    • Brought the backbone network back online across the data center regions
    • Brought services back gradually, managing the rising load to avoid crashes from a traffic surge
    Action items
    • Find ways to simulate the global backbone being taken offline in storm drills
    • Strengthen testing, drills and overall resilience
    Lessons

    The hardening that protects Facebook's data centers against unauthorized access slowed recovery from an outage caused by Facebook's own error, and the author judges that tradeoff worth keeping. Storm drills prepared the teams to bring load back safely, although no drill had yet simulated the global backbone going offline.

  3. Symptoms

    On Sunday 2 June 2019, with user impact beginning between 11:47 and 11:49 US/Pacific, Google Cloud projects in several US regions saw elevated packet loss from network congestion, and some regions became unreachable. Customers saw higher latency, intermittent errors and lost connectivity to instances in us-central1, us-east1, us-east4, us-west2, northamerica-northeast1 and southamerica-east1, while us-west1, Europe and Asia had no regional congestion.

    Trigger

    At 11:45 US/Pacific a relatively rare type of datacenter maintenance event started in one physical location, and the automation that runs it descheduled logical clusters that also held network control plane jobs in other physical locations.

    Root cause
    Component
    Contributing factor
    Detection

    Google engineers were alerted to the failure two minutes after it began and started the incident process used for the most serious production incidents. The first customer notice appeared on the status page at 12:53 US/Pacific.

    Remediation
    • Lowered the priority of less critical network traffic classes to reduce congestion
    • Halted the datacenter automation software responsible for the maintenance event
    • Rescheduled the network control plane and its supporting infrastructure in each location
    • Rebuilt and redistributed the lost network control plane configuration, rolling it out from 14:03
    • Directed service traffic away from the affected regions
    • Moved the Cloud VPN control plane in three regions out of its fail-safe state
    Action items
    • Keep the maintenance automation off until safeguards stop it descheduling jobs in several physical locations at once
    • Harden the cluster management software to reject such requests whatever their origin
    • Reconfigure the network control plane to reject maintenance requests of the type involved
    • Make the network control plane in each location persist its configuration
    • Let the network stay in fail static mode longer when the control plane is lost
    • Review, update and test emergency response tooling and procedures, including customer communication tooling, for such network failures
    • Extend continuous disaster recovery testing to this and similarly catastrophic failures
  4. Symptoms

    At about 08:49 UTC on 2 June 2019, Packet's internal network monitoring alerted on serious reachability and performance problems in several of Packet's global datacenter locations. The first investigation found routing loops and traffic being blackholed to specific internal and Internet destinations.

    Trigger

    A trans-continental US backbone link in the network of Packet's upstream provider Zayo had a hardware failure and blackholed IP traffic routed over it.

    Root cause
    Component
    Contributing factor
    –
    Detection

    Packet's internal network monitoring alerted at 08:49 UTC on reachability issues in several global datacenter locations, and engineers confirmed them at 08:52.

    Remediation
    • Migrated traffic to an alternative network and removed Zayo from the provider mix
    • Applied route filters to return service to normal
    • Optimised specific routing policies to improve latency across the backbone with the new traffic mix
    Action items
    • Expand internal connectivity monitoring and alerting of on-call operations teams
    • Expand network automation and routing so traffic can be balanced across all available backbone paths and an operator can trigger automated re-routes across all Packet datacenters in a major provider incident
    • Make Packet's provisioning systems less dependent on third party network providers and inter-datacenter connectivity
  5. Symptoms

    On 7 February 2019 from 22:17 to 23:25 UTC, some Acquia Cloud Enterprise sites in US-East became unstable or went down for multiple customers. The web servers could not reach the Memcache servers, PHP processes on the web servers were blocked, and the sites became unavailable.

    Trigger

    While setting up a temporary file system to store diagnostic data, a rule was deleted by mistake from a VPC security group.

    Root cause
    Component
    Contributing factor
    Detection

    Acquia's configuration drift alerting fired, but the alert was not seen in time to shorten the outage.

    Remediation
    • Restored the missing rule in the security group by hand
    Action items
    • Correct the internal workflow with all involved teams to prevent similar mistakes
    • Alert internal teams faster about configuration drift in VPC security groups
Check your cluster for this

These 39 cases involve BGP routing and Network control plane (SDN). kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause10

Faulty deployment3 cases

  1. IL-0354 Fly.io private networking (6PN) broke for some machines after edges received gateway /80 routes
    Fly.io2026
  2. IL-0563 Linode servers lost connectivity in all data centers as route servers built incomplete BGP route tables
    Linode2025
  3. IL-0530 Virtual router controllers in us-central1 ran out of memory in a loop, cutting networking for new and migrated VMs

Cloud provider outage4 cases

  1. IL-0463 Secure Connect connectors timed out after a GKE control plane upgrade left Harness's internal load balancer unreachable
  2. IL-0368 PlanetScale's control plane went down and some database branches failed queries during the AWS us-east-1 outage
  3. IL-0261 Discord went fully offline twice as short network losses on Google Cloud sessions nodes wedged Erlang distribution
  4. IL-0494 Netlify's central load balancer IP stopped responding when Rackspace null-routed it in a DDoS, and A-record sites hung

Configuration change8 cases

  1. IL-0400 Public sector sites across Wales lost connectivity for over 8 hours as a PE router wrongly advertised a default route
    PSBA2026
  2. IL-0473 Jenkins infrastructure went fully down after a pod IP range fix deleted every AKS node pool and could not recreate them
  3. IL-0541 Two Twingate Relay clusters were discoverable but unreachable, so Clients and Connectors could not attach to them
  4. IL-0225 An IGP purge command made every Microsoft WAN router recompute routes, causing global latency, timeouts and packet loss
  5. IL-0266 Eqiad routers looped traffic between each other after a BGP MED change and could not reach other sites' public IPs
  6. IL-0539 KT's internet service failed nationwide for about 89 minutes as wrong routes spread from one router in Busan
    KT2021
  7. IL-0228 IPv4 routing across OVHcloud's global network broke after a router change put the full internet routing table into OSPF
  8. IL-0519 Apps on the cloud.gov PaaS became unavailable after an AWS security group change blocked their outbound traffic

Capacity exhaustion2 cases

  1. IL-0350 Hosts in an IONOS TXL cluster lost connectivity when an InfiniBand fabric resweep failed on a full multicast table
  2. IL-0472 Node-to-pod traffic and DNS failed on Tinder's 605-node Flannel cluster when every node's ARP cache passed gc_thresh3
    Tinder2019

Operator error6 cases

  1. IL-0349 IONOS Private Cloud in Berlin lost management access, storage and VM internet routing after a VLAN change
  2. IL-0244 A queued pull request destroyed the EKS subnet route table associations and Cloud Platform services went offline
  3. IL-0221 A backbone maintenance command disconnected all Facebook data centers, and its DNS servers withdrew their BGP routes
    Meta2021
  4. IL-0245 Acquia Cloud Enterprise sites in US-East went down when their web servers could no longer reach the Memcache servers
    Acquia2019
  5. IL-0431 During Mackerel's move to AWS, PostgreSQL failed over to a replica that had stopped replicating, losing an hour of data
    Hatena2017
  6. IL-0337 EBS volumes in one US East Availability Zone got stuck after a network change cut EBS nodes off from their replicas

Breaking change in an upgrade1 case

Organisation
  1. IL-0227 Most Heroku dynos in Private Spaces lost outbound connectivity after an automated OS update restarted host networking
    Heroku2025

Software defect7 cases

  1. IL-0233 A VPC control plane release broke IP alias routes in Nebius eu-west1, and Managed Kubernetes pods lost connectivity
    Nebius2025
  2. IL-0347 About 25% of Scaleway FR-PAR-1 hypervisors lost VPC connectivity when both VPC BGP route reflectors got stuck
  3. IL-0529 New Google Cloud VMs and other instances came up without network connectivity in all zones after VPC controllers stopped
  4. IL-0342 DigitalOcean's AMS3, LON1 and SFO2 data centers lost Internet connectivity in repeated waves as edge routers failed
  5. IL-0344 Linode's US-West data centers in Fremont and Santa Clara lost connectivity as the fibre circuits between them failed
    Linode2023
  6. IL-0222 Google Cloud US regions had heavy packet loss and some went unreachable after the network control plane was descheduled
  7. IL-0396 New or live-migrated GCE instances, VPN tunnels and network load balancers were unreachable on public IPs for over 2h

Dependency failure6 cases

  1. IL-0526 OpenStreetMap.org went offline, then read-only, for 56 hours after HE.net routing equipment cut both fibre uplinks
  2. IL-0509 SourceHut was down for 170 hours after a DDoS led its upstream network to null-route the PHL datacenter's subnet
  3. IL-0259 Outbound packets from Fastmail did not reach part of the internet for about 19 hours, cutting off 3-5% of customers
  4. IL-0267 Wikimedia's eqsin cache site went unreachable when both of its transport links to the core data centers were down
  5. IL-0358 Packet Public Cloud locations had high latency and unreachable paths from routing loops and blackholed traffic
    Packet2019
  6. IL-0258 FastMail was unreachable for almost two hours when the GRE tunnels carrying its traffic from Level 3 went down

DNS or network fault1 case

Contributing factor
–
Organisation
  1. IL-0423 A core switch failure in Paperspace's NY2 region cut VMs off their network file system and left them read-only

Hardware failure1 case

  1. IL-0525 OpenStreetMap.org went offline for 7h 27m when its uplink switch lost power during a data-centre power feed maintenance