  1. Symptoms

    On 7 August 2017, while checking the application after the maintenance that moved Mackerel from an on-premises data center to AWS, the team found that data updated during a specific time window was missing. Everything written to the PostgreSQL database between 14:30 and 15:30 JST was gone.

    Trigger

    One hour after the application was switched to the newly promoted primary db001, db001 lost network connectivity and the database failed over to the standby db002.

    Root cause
    Component
    Contributing factor
    Detection

    The team found the missing data while checking how the application behaved after the migration work.

    Remediation
    • Tried to restore the lost updates by hand from the table data left on db001 and gave up
    • Tried point-in-time recovery from the base backup and WAL and gave up
    • Built a new replica db003 with db002 as primary to restore redundancy
    • Kept db001 in maintenance state for investigation
    • Watched db002 for some time to confirm the problem did not recur, then completed the migration
    Action items
    • Change the PostgreSQL replica creation script to set recovery_target_timeline = 'latest' in recovery.conf by default
    • Add a check to a server configuration test tool such as Serverspec that recovery.conf contains recovery_target_timeline = 'latest'
    Lessons

    A setting needed only for a rare layout, such as a grandchild replica during a migration, was applied by hand through a script option and was forgotten. Because recovery_target_timeline = 'latest' is harmless on ordinary standbys too, Hatena now sets it by default whenever a replica is created. The staging rehearsal used the same layout and steps but had the setting right, so it could not catch the mistake. Hatena notes that a similar layout may be used again for a future PostgreSQL upgrade or a move to another region.

  2. Symptoms

    On 30 January 2017, Google Compute Engine instances, Cloud VPN tunnels and GCE network load balancers that were created or live migrated between 10:36 and 12:42 PDT could not be reached on their public IP addresses. Resources created earlier, and instances that were not live migrated, kept working.

    Trigger

    A large set of updates was applied to a rarely used load balancing configuration on the shared layer 2 load balancers.

    Root cause
    Component
    Contributing factor
    Remediation
    • Restarted the jobs that program changes into the network load balancers, so the stuck changes were processed as a batch
    • Applied the fix zone by zone between 11:36 and 12:42
    Action items
    • Increase the canary timeout so updates that hit the inefficient code path only slow network changes instead of stopping them
    • Improve the inefficient code path
    • Write new tests that check behaviour on a wider range of configurations
    • Accelerate replacing global propagation of address configuration with decentralized routing
    • Add metrics and alerting that identify this kind of issue sooner
  3. Symptoms

    At 8am PST on Monday, August 22, 2016, Netlify got alerts that its central load balancer, the single public IP that users point A records at, had stopped responding. Rackspace had null-routed the load balancer, so all traffic to that IP hung before it reached Netlify's servers.

    Trigger

    A DDoS attack against Netlify's central load balancer in Rackspace's Chicago datacenter, after which Rackspace null-routed the load balancer's public IP.

    Root cause
    Component
    Contributing factor
    Detection

    Alerts at 8am PST reported that the central load balancer had stopped responding, and Rackspace then confirmed it had null-routed the load balancer.

    Remediation
    • Started a new cluster of CDN machines in Google Compute behind a Google network load balancer
    • Gave clients who had contacted support the new public IP and told them to change their A records
    • Updated the documentation and announced the new IP on Twitter, Gitter and the status page
    Action items
    • Keep the new Google-based network IP running in place of the Rackspace load balancer
    • Release Netlify's own DNS hosting, integrated with the CDN, so domains do not depend on a fixed IP
    • Fix the status page publishing process so it is updated straight away during an issue
    • Build a mailer that sends targeted mails to all paying clients during an outage
    Lessons

    Netlify judged Rackspace's load balancer too vulnerable to DDoS and Rackspace's DDoS processes not up to the standard of other cloud providers, and expected Google's anycast-based Maglev load balancer to be more resilient. In the end, the only way to protect a domain from DDoS-related outages is not to expose any fixed IP address for it, which is why sites should use the www domain with a CNAME, or Netlify DNS, rather than a single A-record IP.

  4. Symptoms

    From 9:28am Pacific Time on 8 March 2016, applications on the cloud.gov PaaS that relied on outbound traffic to reach the services they depended on became unavailable, and at one point every application on cloud.gov was down.

    Trigger

    At 9:28am Pacific Time on 8 March 2016 a contractor at Aquilent changed the AWS security group settings, one of several changes made in the process of achieving ATO for the platform.

    Root cause
    Component
    Contributing factor
    –
    Remediation
    • Added exceptions for individual applications, which restored some of them
    • Rolled back the security group change, which restored all applications
    Action items
    • Put all security group configuration into version control and make changes through pull requests
    • Monitor the applications running on cloud.gov and alert the cloud.gov team when they do not work as expected
    • Use CF security groups instead of AWS security groups and make the current rules visible to the cloud.gov team and the teams using it
    • Create a notification system to reach the key contact of each application on the platform
    • Create a more accurate staging environment to test changes like this
  5. Symptoms

    At 4.50am Melbourne time on Sunday 7 February (evening of 6 February UTC), FastMail became unavailable and stayed unreachable for almost two hours. Traffic to FastMail's public IP range never made it into FastMail's own network.

    Trigger

    The GRE tunnels between Level 3 and NYI, which carried FastMail's filtered traffic into its network, went down.

    Root cause
    Component
    Contributing factor
    Detection

    NYI, the datacentre provider, noticed the failure quickly.

    Remediation
    • NYI escalated with Level 3's support until FastMail's public IP ranges were pointed back to NYI
    Action items
    • Go back to DDoS protection from Black Lotus under NYI's explicit control
    • Build nginx frontends in the Los Angeles datacentre that reach NYI over the secondary network, and point DNS to them if NYI's primary network fails
    • Add hardware in Amsterdam and change the delivery system so it depends less on NYI
    • Work with NYI to understand its processes for detecting and responding to network faults
    Lessons

    Much of FastMail's and NYI's reliability had come from NYI controlling its own infrastructure. With protection always on at Level 3, NYI could not restore the routes itself, and FastMail calls the resulting delay in restoring service unacceptable.

Check your cluster for this

These 39 cases involve BGP routing and Network control plane (SDN). kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause10

Faulty deployment3 cases

  1. IL-0354 Fly.io private networking (6PN) broke for some machines after edges received gateway /80 routes
    Fly.io2026
  2. IL-0563 Linode servers lost connectivity in all data centers as route servers built incomplete BGP route tables
    Linode2025
  3. IL-0530 Virtual router controllers in us-central1 ran out of memory in a loop, cutting networking for new and migrated VMs

Cloud provider outage4 cases

  1. IL-0463 Secure Connect connectors timed out after a GKE control plane upgrade left Harness's internal load balancer unreachable
  2. IL-0368 PlanetScale's control plane went down and some database branches failed queries during the AWS us-east-1 outage
  3. IL-0261 Discord went fully offline twice as short network losses on Google Cloud sessions nodes wedged Erlang distribution
  4. IL-0494 Netlify's central load balancer IP stopped responding when Rackspace null-routed it in a DDoS, and A-record sites hung

Configuration change8 cases

  1. IL-0400 Public sector sites across Wales lost connectivity for over 8 hours as a PE router wrongly advertised a default route
    PSBA2026
  2. IL-0473 Jenkins infrastructure went fully down after a pod IP range fix deleted every AKS node pool and could not recreate them
  3. IL-0541 Two Twingate Relay clusters were discoverable but unreachable, so Clients and Connectors could not attach to them
  4. IL-0225 An IGP purge command made every Microsoft WAN router recompute routes, causing global latency, timeouts and packet loss
  5. IL-0266 Eqiad routers looped traffic between each other after a BGP MED change and could not reach other sites' public IPs
  6. IL-0539 KT's internet service failed nationwide for about 89 minutes as wrong routes spread from one router in Busan
    KT2021
  7. IL-0228 IPv4 routing across OVHcloud's global network broke after a router change put the full internet routing table into OSPF
  8. IL-0519 Apps on the cloud.gov PaaS became unavailable after an AWS security group change blocked their outbound traffic

Capacity exhaustion2 cases

  1. IL-0350 Hosts in an IONOS TXL cluster lost connectivity when an InfiniBand fabric resweep failed on a full multicast table
  2. IL-0472 Node-to-pod traffic and DNS failed on Tinder's 605-node Flannel cluster when every node's ARP cache passed gc_thresh3
    Tinder2019

Operator error6 cases

  1. IL-0349 IONOS Private Cloud in Berlin lost management access, storage and VM internet routing after a VLAN change
  2. IL-0244 A queued pull request destroyed the EKS subnet route table associations and Cloud Platform services went offline
  3. IL-0221 A backbone maintenance command disconnected all Facebook data centers, and its DNS servers withdrew their BGP routes
    Meta2021
  4. IL-0245 Acquia Cloud Enterprise sites in US-East went down when their web servers could no longer reach the Memcache servers
    Acquia2019
  5. IL-0431 During Mackerel's move to AWS, PostgreSQL failed over to a replica that had stopped replicating, losing an hour of data
    Hatena2017
  6. IL-0337 EBS volumes in one US East Availability Zone got stuck after a network change cut EBS nodes off from their replicas

Breaking change in an upgrade1 case

Organisation
  1. IL-0227 Most Heroku dynos in Private Spaces lost outbound connectivity after an automated OS update restarted host networking
    Heroku2025

Software defect7 cases

  1. IL-0233 A VPC control plane release broke IP alias routes in Nebius eu-west1, and Managed Kubernetes pods lost connectivity
    Nebius2025
  2. IL-0347 About 25% of Scaleway FR-PAR-1 hypervisors lost VPC connectivity when both VPC BGP route reflectors got stuck
  3. IL-0529 New Google Cloud VMs and other instances came up without network connectivity in all zones after VPC controllers stopped
  4. IL-0342 DigitalOcean's AMS3, LON1 and SFO2 data centers lost Internet connectivity in repeated waves as edge routers failed
  5. IL-0344 Linode's US-West data centers in Fremont and Santa Clara lost connectivity as the fibre circuits between them failed
    Linode2023
  6. IL-0222 Google Cloud US regions had heavy packet loss and some went unreachable after the network control plane was descheduled
  7. IL-0396 New or live-migrated GCE instances, VPN tunnels and network load balancers were unreachable on public IPs for over 2h

Dependency failure6 cases

  1. IL-0526 OpenStreetMap.org went offline, then read-only, for 56 hours after HE.net routing equipment cut both fibre uplinks
  2. IL-0509 SourceHut was down for 170 hours after a DDoS led its upstream network to null-route the PHL datacenter's subnet
  3. IL-0259 Outbound packets from Fastmail did not reach part of the internet for about 19 hours, cutting off 3-5% of customers
  4. IL-0267 Wikimedia's eqsin cache site went unreachable when both of its transport links to the core data centers were down
  5. IL-0358 Packet Public Cloud locations had high latency and unreachable paths from routing loops and blackholed traffic
    Packet2019
  6. IL-0258 FastMail was unreachable for almost two hours when the GRE tunnels carrying its traffic from Level 3 went down

DNS or network fault1 case

Contributing factor
–
Organisation
  1. IL-0423 A core switch failure in Paperspace's NY2 region cut VMs off their network file system and left them read-only

Hardware failure1 case

  1. IL-0525 OpenStreetMap.org went offline for 7h 27m when its uplink switch lost power during a data-centre power feed maintenance